TY - GEN
T1 - Algorithm Oriented to the Detection of the Level of Blood Filling in Venipuncture Tubes Based on Digital Image Processing
AU - Castillo, Jorge
AU - Apfata, Nelson
AU - Kemper, Guillermo
N1 - Publisher Copyright:
© 2021, The Editor(s) (if applicable) and The Author(s), under exclusive license to Springer Nature Switzerland AG.
PY - 2021
Y1 - 2021
N2 - This article proposes an algorithm oriented to the detection of the level of blood filling in patients, with detection capacity in millimeters. The objective of the software is to detect the amount of blood stored into the venipuncture tube and avoid coagulation problems due to excess fluid. It also aims to avoid blood levels below that required, depending on the type of analysis to be performed. The algorithm acquires images from a camera positioned in a rectangular structure located within an enclosure, which has its own internal lighting to ensure adequate segmentation of the pixels of the region of interest. The algorithm consists of an image improvement stage based on gamma correction, followed by a segmentation stage of the area of pixels of interest, which is based on thresholding by HSI model, in addition to filtering to accentuate the contrast between the level of filling and staining, and as a penultimate stage, the location of the filling level due to changes in the vertical tonality of the image. Finally, the level of blood contained in the tube is obtained from the detection of the number of pixels that make up the vertical dimension of the tube filling. This number of pixels is then converted to physical dimensions expressed in millimeters. The validation results show an average percentage error of 0.96% by the proposed algorithm.
AB - This article proposes an algorithm oriented to the detection of the level of blood filling in patients, with detection capacity in millimeters. The objective of the software is to detect the amount of blood stored into the venipuncture tube and avoid coagulation problems due to excess fluid. It also aims to avoid blood levels below that required, depending on the type of analysis to be performed. The algorithm acquires images from a camera positioned in a rectangular structure located within an enclosure, which has its own internal lighting to ensure adequate segmentation of the pixels of the region of interest. The algorithm consists of an image improvement stage based on gamma correction, followed by a segmentation stage of the area of pixels of interest, which is based on thresholding by HSI model, in addition to filtering to accentuate the contrast between the level of filling and staining, and as a penultimate stage, the location of the filling level due to changes in the vertical tonality of the image. Finally, the level of blood contained in the tube is obtained from the detection of the number of pixels that make up the vertical dimension of the tube filling. This number of pixels is then converted to physical dimensions expressed in millimeters. The validation results show an average percentage error of 0.96% by the proposed algorithm.
KW - Blood draw
KW - Detection
KW - Filling level
KW - Image processing
KW - Venipuncture tube
UR - https://www.scopus.com/pages/publications/85098193318
U2 - 10.1007/978-3-030-57566-3_1
DO - 10.1007/978-3-030-57566-3_1
M3 - Contribución a la conferencia
AN - SCOPUS:85098193318
SN - 9783030575656
T3 - Smart Innovation, Systems and Technologies
SP - 3
EP - 15
BT - Proceedings of the 5th Brazilian Technology Symposium - Emerging Trends, Issues, and Challenges in the Brazilian Technology
A2 - Iano, Yuzo
A2 - Arthur, Rangel
A2 - Saotome, Osamu
A2 - Kemper, Guillermo
A2 - Borges Monteiro, Ana Carolina
PB - Springer Science and Business Media Deutschland GmbH
T2 - 5th Brazilian Technology Symposium, BTSym 2019
Y2 - 22 October 2019 through 24 October 2019
ER -