Comparison Between Peruvian Standards E.030 from 2006 and 2016 Through a Static Nonlinear Analysis in a Six-Story Reinforced Concrete Building

Christian J. Seminario, Fernando A. Velasco, Joan R. Casas, Rick M. Delgadillo

Producción científica: Capítulo del libro/informe/acta de congresoContribución a la conferenciarevisión exhaustiva

Resumen

In this article, a non-linear Pushover analysis is developed for a porticoed building in La Perla - Callao, which was built in 2011 and was designed with the current standard E.030 Earthquake-resistant Design of 2006. This analysis is subsequently used to obtain of mezzanine drifts along with the damage states and performance levels of the building. These results are compared with a new analysis of the same building in question using the current standard Peruvian Technical Standard E.030 – 2016 to know how the behavior of the structure changes in the face of the change of standard based on the change in numerical values of the stipulated parameters, such as those used in the ZUCS/R analysis, factors which were changed to guarantee structural non-collapse and safeguard human life and integrity. Finally, it is concluded that the factors analyzed do not significantly influence the change in the capacity spectra and therefore a state of damage can be maintained depending on the characteristics of the building.

Idioma originalInglés
Título de la publicación alojadaProceedings of 7th International Conference on Civil Engineering and Architecture, Volume 1 - Proceedings of ICCEA 2024
EditoresThomas Kang, Youngjin Lee
EditorialSpringer Science and Business Media Deutschland GmbH
Páginas302-312
Número de páginas11
ISBN (versión impresa)9789819661145
DOI
EstadoPublicada - 2025
Evento7th International Conference on Civil Engineering and Architecture, ICCEA 2024 - Da Nang, Vietnam
Duración: 7 dic. 20249 dic. 2024

Serie de la publicación

NombreLecture Notes in Civil Engineering
Volumen640 LNCE
ISSN (versión impresa)2366-2557
ISSN (versión digital)2366-2565

Conferencia

Conferencia7th International Conference on Civil Engineering and Architecture, ICCEA 2024
País/TerritorioVietnam
CiudadDa Nang
Período7/12/249/12/24

Huella

Profundice en los temas de investigación de 'Comparison Between Peruvian Standards E.030 from 2006 and 2016 Through a Static Nonlinear Analysis in a Six-Story Reinforced Concrete Building'. En conjunto forman una huella única.

Citar esto