TY - JOUR
T1 - In vitro comparison of the immediate adhesive strength in dentin of three universal adhesive systems.
AU - Acurio-Benavente, Mariana
AU - Kinoshita-Rivas, Haru
AU - Acurio-Benavente, Paloma
AU - Casas-Apayco, Leslie
N1 - Publisher Copyright:
© 2018, Universidad de Concepcion. All rights reserved.
PY - 2018/5/31
Y1 - 2018/5/31
N2 - Objective: To compare the adhesive strength in dentin of three universal adhesive systems in vitro by means of the shear test. Materials and methods: Seventy-five bovine teeth were selected and cut. Dentin was exposed from the buccal surface of the crowns with 220 grit sandpaper, and samples were then inserted in transparent acrylic bases (15x10mm). The samples were randomly divided in 3 groups (n=25): G1-Universal adhesive system Scotchbond™ Universal (3M ESPE-USA); G2-Universal adhesive system Peak Universal Bond (Ultradent); G3-Universal adhesive system Tetric N-Bond (Ivoclar Vivadent). The adhesive procedures were carried out according to the instructions of each manufacturer and the restorative procedures were carried out with micro-cylinders (made of Tygon type tubing 0.79x1.5mm) of the composite resin Filtek™ Z350XT-A2 (3M ESPE-USA). The samples were incubated at 37ºC (+/-5ºC) for 24 hours. Adhesive strength was evaluated in a universal test machine by means of the shear test (0.5mm/ min, 500N) and the resulting fracture type was evaluated with a Dinolite digital microscope (x200). The results were analyzed by descriptive statistics (Mean±SD), and inferential statistics by a one-way ANOVA. Results: No statistically significant differences were found between the universal adhesive systems evaluated G1 (14.91±4.76), G2 (16.90±4.11) and G3 (17.34±4.04)/(p=0.114). Conclusions: The shear test resulted in similar values of immediate adhesive strength of the three universal adhesive systems used.
AB - Objective: To compare the adhesive strength in dentin of three universal adhesive systems in vitro by means of the shear test. Materials and methods: Seventy-five bovine teeth were selected and cut. Dentin was exposed from the buccal surface of the crowns with 220 grit sandpaper, and samples were then inserted in transparent acrylic bases (15x10mm). The samples were randomly divided in 3 groups (n=25): G1-Universal adhesive system Scotchbond™ Universal (3M ESPE-USA); G2-Universal adhesive system Peak Universal Bond (Ultradent); G3-Universal adhesive system Tetric N-Bond (Ivoclar Vivadent). The adhesive procedures were carried out according to the instructions of each manufacturer and the restorative procedures were carried out with micro-cylinders (made of Tygon type tubing 0.79x1.5mm) of the composite resin Filtek™ Z350XT-A2 (3M ESPE-USA). The samples were incubated at 37ºC (+/-5ºC) for 24 hours. Adhesive strength was evaluated in a universal test machine by means of the shear test (0.5mm/ min, 500N) and the resulting fracture type was evaluated with a Dinolite digital microscope (x200). The results were analyzed by descriptive statistics (Mean±SD), and inferential statistics by a one-way ANOVA. Results: No statistically significant differences were found between the universal adhesive systems evaluated G1 (14.91±4.76), G2 (16.90±4.11) and G3 (17.34±4.04)/(p=0.114). Conclusions: The shear test resulted in similar values of immediate adhesive strength of the three universal adhesive systems used.
KW - Adhesives
KW - Dentin
KW - Shear strength
UR - https://www.scopus.com/pages/publications/85048254224
U2 - 10.17126/joralres.2018.044
DO - 10.17126/joralres.2018.044
M3 - Artículo
AN - SCOPUS:85048254224
SN - 0719-2479
VL - 7
SP - 173
EP - 177
JO - Journal of Oral Research
JF - Journal of Oral Research
IS - 5
ER -